% If you do scans with different marks for energy you can use this code to
|
||
% calibrate the marks vs energy
|
||
% Run this code, it will save a calibration and then you can use
|
||
% energy2mark function
|
||
|
||
% User input
|
||
scans = [134:163];
|
||
marks = [0:0.2:5.99];
|
||
|
||
data = io.spec_read('~/Data10/','ScanNr',scans);
|
||
|
||
clear E
|
||
for ii = 1:numel(data)
|
||
E(ii) = data{ii}.mokev;
|
||
end
|
||
|
||
% Remove the last
|
||
E = E(1:end-1);
|
||
marks = marks(1:end-1);
|
||
|
||
figure(1);
|
||
plot(E,marks,'o-')
|
||
xlabel('E (keV)')
|
||
ylabel('marks')
|
||
|
||
save('mark_calib.mat','marks','E');
|
||
|
||
%*-----------------------------------------------------------------------*
|
||
%| |
|
||
%| Except where otherwise noted, this work is licensed under a |
|
||
%| Creative Commons Attribution-NonCommercial-ShareAlike 4.0 |
|
||
%| International (CC BY-NC-SA 4.0) license. |
|
||
%| |
|
||
%| Copyright (c) 2017 by Paul Scherrer Institute (http://www.psi.ch) |
|
||
%| |
|
||
%| Author: CXS group, PSI |
|
||
%*-----------------------------------------------------------------------*
|
||
% You may use this code with the following provisions:
|
||
%
|
||
% If the code is fully or partially redistributed, or rewritten in another
|
||
% computing language this notice should be included in the redistribution.
|
||
%
|
||
% If this code, or subfunctions or parts of it, is used for research in a
|
||
% publication or if it is fully or partially rewritten for another
|
||
% computing language the authors and institution should be acknowledged
|
||
% in written form in the publication: “Data processing was carried out
|
||
% using the “cSAXS matlab package” developed by the CXS group,
|
||
% Paul Scherrer Institut, Switzerland.”
|
||
% Variations on the latter text can be incorporated upon discussion with
|
||
% the CXS group if needed to more specifically reflect the use of the package
|
||
% for the published work.
|
||
%
|
||
% A publication that focuses on describing features, or parameters, that
|
||
% are already existing in the code should be first discussed with the
|
||
% authors.
|
||
%
|
||
% This code and subroutines are part of a continuous development, they
|
||
% are provided “as they are” without guarantees or liability on part
|
||
% of PSI or the authors. It is the user responsibility to ensure its
|
||
% proper use and the correctness of the results. |