mirror of
https://github.com/c-sooyoung/fold_slice.git
synced 2026-09-17 17:29:09 +09:00
70 lines
3.4 KiB
Matlab
70 lines
3.4 KiB
Matlab
% this script contains the necessary loop for 'find_capillary.m' to be called
|
||
% as function of 'spec'
|
||
% written by (last change: 2011-06-16)
|
||
% in case of bugs, problems, and suggestions for improvements, please contact
|
||
% CXS group
|
||
%
|
||
% note that EPICS communication works only on local machines at the beamline, i.e.,
|
||
% NOT on the compute nodes
|
||
% run this (or related scripts that use EPICS for communication), for instance, on
|
||
% x12sa-cons-1
|
||
|
||
%*-----------------------------------------------------------------------*
|
||
%| |
|
||
%| Except where otherwise noted, this work is licensed under a |
|
||
%| Creative Commons Attribution-NonCommercial-ShareAlike 4.0 |
|
||
%| International (CC BY-NC-SA 4.0) license. |
|
||
%| |
|
||
%| Copyright (c) 2017 by Paul Scherrer Institute (http://www.psi.ch) |
|
||
%| |
|
||
%| Author: CXS group, PSI |
|
||
%*-----------------------------------------------------------------------*
|
||
% You may use this code with the following provisions:
|
||
%
|
||
% If the code is fully or partially redistributed, or rewritten in another
|
||
% computing language this notice should be included in the redistribution.
|
||
%
|
||
% If this code, or subfunctions or parts of it, is used for research in a
|
||
% publication or if it is fully or partially rewritten for another
|
||
% computing language the authors and institution should be acknowledged
|
||
% in written form in the publication: “Data processing was carried out
|
||
% using the “cSAXS matlab package” developed by the CXS group,
|
||
% Paul Scherrer Institut, Switzerland.”
|
||
% Variations on the latter text can be incorporated upon discussion with
|
||
% the CXS group if needed to more specifically reflect the use of the package
|
||
% for the published work.
|
||
%
|
||
% A publication that focuses on describing features, or parameters, that
|
||
% are already existing in the code should be first discussed with the
|
||
% authors.
|
||
%
|
||
% This code and subroutines are part of a continuous development, they
|
||
% are provided “as they are” without guarantees or liability on part
|
||
% of PSI or the authors. It is the user responsibility to ensure its
|
||
% proper use and the correctness of the results.
|
||
|
||
lastscan = 0;
|
||
|
||
while(1)
|
||
scall = sprintf('caget ''X12SA-ES1-DOUBLE-00''');
|
||
[err,io] = system(scall);
|
||
arrout = regexp(io,' +','split');
|
||
scannr = str2double(arrout{2});
|
||
if (scannr > lastscan)
|
||
try
|
||
COM = +beamline.find_capillary('..','ScanNr',scannr,'Counter','diode')
|
||
catch
|
||
fprintf('Failed find capillary, pausing 5 sec and retrying\n')
|
||
pause(5)
|
||
COM = +beamline.find_capillary('..','ScanNr',scannr,'Counter','diode')
|
||
end
|
||
else
|
||
pause(1);
|
||
end
|
||
scall = sprintf('caputq X12SA-ES1-DOUBLE-02 %f',COM);
|
||
[err,io] = system(scall);
|
||
scall = sprintf('caputq X12SA-ES1-DOUBLE-01 %d',scannr);
|
||
[err,io] = system(scall);
|
||
lastscan = scannr;
|
||
end
|